To control water levels in dams and reservoirs over long distances. One Float Switch – 2 wire control When the float contact is closed between terminals 5+7, the relay is energised. On opening the float contacts the relay will de-energise. Two Float Switch – 3 wire control: For correct operation the Stop float must first close between terminals 6+7. On this closure the Stop relay (STR) energises and makes contact between terminals 2+8. The Start float is connected between 5+6 and on closure energises the ON relay. This relay remains energised until the Stop float opens between 6+7. The ON and STR relays are then both de-energised. The STR relay is used for switching the electrical supply ON or OFF to the pump relay circuitry in the control panel. Float terminal volts = 24V DC. Distance: up to 4 km using 1.5mm copper wire/cable. If more than one DCU is installed, interconnection of the outputs must be avoided.
Avanti DCU 400V
R1,009.00
Availability: 6 in stock (can be backordered)
| MPN | 300DCU140STR |
|---|